4
Communication Objects
36/79 ekr CON 600 net – Process Data Exchange via Profibus
4.1.2.8 EkrIn_Web width
Slot 8
Slot Name ADI_Data_8_1
Object EkrIn_Web width
Function Web width measurement –
Specifying the reference material width for the calibration of the web width
measurement
The set value is accepted when the takeover bit is written.
Data types Unsigned8, SInteger32
Access Write-only
Object length 6 bytes
Name Data Type Bit Meaning Data Description
Parameter
selection bit field
Unsigned8 1 Width Set Value
The following data becomes valid if the
corresponding bit in this parameter
selection bit field is set (see Using the
Parameter Selection Bit Field, page 17).
Padding byte Unsigned8 Padding byte Unusable
Width Set Value SInteger32 Reference material width Unit: µm
4.1.2.9 EkrOut_Web width
Slot 9
Slot Name ADI_Data_9_1
Object EkrOut_Web width
Function Web width measurement –
Reading and validation of the measured web width
Data types Unsigned8, SInteger32
Access Read-only
Object length 6 bytes
Name Data Type Bit Meaning Data Description
Web width SInterger32 Measured web width Unit: µm
Width valid Unsigned8
0 Web width is valid
The measured value for the material
web width can only be used if the
corresponding validation flag has the
status1.
1 Web width is invalid
Padding byte Unsigned8 Padding byte Unusable