Communication Objects
4
ekr CON 600 net – Process Data Exchange via Profibus 59/79
4.2.2.18 ClsIn_JobInterface
Slot 2
Index 69
Object ClsIn_JobInterface
Function Access to the setup administration of the CLSPro600 line and contrast sensor
(loading, saving and deleting of setup slots)
Data types Unsigned8
Access Read & Write
Object length 4 bytes
Name Data Type Bit Meaning Data Description
Parameter
selection bit field
Unsigned8
0 Load Slot The following data
becomes valid if the
corresponding bit in this
parameter selection bit
field is set (see Using the
Parameter Selection Bit
Field, page 17).
1 Write Slot
2 Delete Slot
3
…
7
Reserved
Load Slot Unsigned8 Loading and activating the setup slot
Note:
The CLS status word
must be considered.
Write Slot Unsigned8
Saving the current setup under the slot
with the specified index (1 … 32)
Delete Slot Unsigned8
Deleting the slot with the transferred
index (1 … 32)