Communication Objects
4
ekr CON 600 net – Process Data Exchange via Profibus 59/79
4.2.2.18 ClsIn_JobInterface
Slot 2
Index 69
Object ClsIn_JobInterface
Function Access to the setup administration of the CLSPro600 line and contrast sensor
(loading, saving and deleting of setup slots)
Data types Unsigned8
Access Read & Write
Object length 4 bytes
Name Data Type Bit Meaning Data Description
Parameter
selection bit field
Unsigned8
0 Load Slot The following data
becomes valid if the
corresponding bit in this
parameter selection bit
field is set (see Using the
Parameter Selection Bit
Field, page 17).
1 Write Slot
2 Delete Slot
3
7
Reserved
Load Slot Unsigned8 Loading and activating the setup slot
Note:
The CLS status word
must be considered.
Write Slot Unsigned8
Saving the current setup under the slot
with the specified index (1 … 32)
Delete Slot Unsigned8
Deleting the slot with the transferred
index (1 … 32)

Table of Contents

Other manuals for BST ekr CON 600 net

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the BST ekr CON 600 net and is the answer not in the manual?

BST ekr CON 600 net Specifications

General IconGeneral
BrandBST
Modelekr CON 600 net
CategoryController
LanguageEnglish

Related product manuals