Communication Objects
4
ekr CON 600 net – Process Data Exchange via Profibus 49/79
4.2.2.4 Sensor Mode
Slot 2
Index 26
Name Sensor Mode
Function Selecting the operating mode for the IR2011/40 edge sensor
Six different operating modes can be selected for the IR2011/40 optical edge sensor
(Standard, Narrow, Marginal Perforation, Nonwoven, Dynamic, Auto Setup).
The operating modes allow optimum adaptation of the sensor's scanning behaviour to
different material properties. A description of the six operating modes can be found in
the operating manual of the ekrCON600net controller, document number MD.542.
Data types Unsigned8, Unsigned16
Access Read & Write
Object length 10 bytes
Name Data Type Bit Meaning Data Description
Parameter selection
bit field
Unsigned8
0 SEN1 (edge sensor1)
The following data becomes
valid if the corresponding bit in
this parameter selection bit field
is set (see Using the Parameter
Selection Bit Field, page 17).
1 SEN2 (edge sensor2)
2 SEN3 (edge sensor3)
3 SEN4 (edge sensor4)
4 Reserved
5 Reserved
6 Reserved
7 Reserved
Padding byte Unsigned8 Padding byte Unusable
SEN1 Unsigned16
0h: Standard
Sensor measuring range:
24mm (±12mm)
1h: Narrow
Sensor measuring range:
7mm (±3.5mm)
2h: Marginal Perforation
Sensor measuring range:
7mm (±3.5mm)
3h: Nonwoven
Sensor measuring range:
24mm (±12mm)
4h: Dynamic
Sensor measuring range:
24mm (±12mm)
5h: Auto Setup
Sensor measuring range:
20mm (±10mm)
SEN2 Unsigned16
See description under SEN1SEN3 Unsigned16
SEN4 Unsigned16