Communication Objects
4
ekr CON 600 net – Process Data Exchange via Profibus 63/79
4.2.2.21 FW Internal 1
Slot 3
Index 224
Name FW Internal 1
Function Reserved for internal use
4.2.2.22 FW Internal 2
Slot 3
Index 225
Name FW Internal 2
Function Reserved for internal use
4.2.2.23 FW Update Command Field
Slot 3
Index 228
Name FW Update Command Field
Function Control commands for firmware updates
Only for use by the BST service.
Data types UInteger32
Access Read & Write
Object length 4 bytes
4.2.2.24 FW Update File Size
Slot 3
Index 229
Name FW Update File Size
Function Reading the determined file size of the firmware file to be copied
The value is used to calculate the progress indicator.
Data types UInteger32
Access Read-only
Object length 4 bytes
Name Data Type Meaning Example
FW Update File Size UInteger32 File size of the firmware file