4
Communication Objects
50/79 ekr CON 600 net – Process Data Exchange via Profibus
4.2.2.5 Sensor Abilities
Slot 2
Index 27
Name Sensor Abilities
Function Reading the sensor abilities
The object provides information about the implemented operating modes of a connected
edge sensor.
Data types Unsigned16
Access Read-only
Object length 8 Byte
Name Data Type Meaning Data Description
SEN1 Unsigned16
Implemented operating mode
of edge sensor1
0x0000: Edge sensor without special
function
0x0001: Edge sensor with Standard
operating mode
0x0002: Edge sensor with Narrow
operating mode
0x0004: Edge sensor with Marginal
Perforation operating mode
0x0008: Edge sensor with Nonwoven
operating mode
0x0010: Edge sensor with Dynamic
operating mode
0x0020: Edge sensor with Auto Setup
operating mode
SEN2 Unsigned16
See description under SEN1SEN3 Unsigned16
SEN4 Unsigned16