155
Type 8692, 8693
english
DeviceNet
12 CONFIGURATION EXAMPLE 2
This example describes the principle procedure for setting up the process image of a DeviceNet master/scanner using the soft-
ware RSNetWorx for DeviceNet (Rev. 4.12.00).
Setting up the scan list and setting the I/O parameters
First of all the scan list of the DeviceNet master/scanner is set up. To do this, the devices listed in the left part of the correspond-
ing window are included in the scan list in the right part of the window. Then the I/O parameters can be changed for each device
included in the scan list. This is required if assemblies which differ from the default settings were selected during configuration
of the positioner in question.
Fig. 10 indicates the setting of the I/O parameters when
Input Assembly POS+CMD+ERR (5 bytes long) is selected and when
Output Assembly INP (2 bytes long; Default Assembly - no change required) is selected
Fig. 10: Screenshot - DeviceNet - Fig. 4