122 Premio/Averso - 13/14 - Ausgabe 09/13 - 2354619 - BUE-0048-12EN
Appliances
9
9.4.1 Models with waste gas vent on the right-hand side of the
vehicle
9.4.2 Truma boiler (special equipment)
Operating modes The boiler has three operating modes:
z Gas operation
z 230 V electrical operation
z Combined operation
The operating mode is set with the operating controls.
The regulation of the water temperature in the boiler is only possible with gas
operation.
Gas operation The boiler is operated exclusively with gas.
Switching on:
Remove cap from waste gas vent.
Open the regulator tap on the gas bottle and the gas isolator tap "Boiler".
Set the rotary switch (Fig. 156,3) to " " (Fig. 156,5). The green "Opera-
tion" indicator lamp illuminates the knob (Fig. 156,1).
Adjust the knob (Fig. 156,1) to the required water temperature.
The red indicator lamp (Fig. 156,2) illuminates when there is a fault (see
chapter 14).
Switching off:
Set the rotary switch (Fig. 156,3) on the operating unit (Fig. 156) to " "
(Fig. 156,4).
Close the gas isolator tap "Boiler" and the regulator tap on the gas bottle.
Place cap on waste gas vent.
The red indicator lamp (Fig. 156,2) illuminates when there is a fault (see
chapter 14).
X If the awning is put up and the boiler is running in gas operation, exhaust
gases from the boiler can escape into the awning area. Danger of suffo-
cation! Make sure the area is sufficiently ventilated.
X Remove cap from waste gas vent before using the Truma boiler.
Fig. 156 Operating unit for Truma boiler
(gas operation)
1 Temperature control knob
2 Red indicator lamp "Fault"
3 Rotary switch
4Off
5On

Table of Contents