93
Action Description
Rest Time
(rest for 000:00:00)
Applies no current for the specified time period
(hhh:mm:ss)*.
The time must be specified or the cycle is skipped.
OhmTest Performs the OhmTest on the battery.
Test
The test cycle has three parts:
The
IF
statement, which describes a condition that must be either true or false for the
battery being tested.
The
THEN
statement, which describes the action to be taken if the battery passes the
test (the condition is true).
The
ELSE
statement, which describes the action to be taken if the battery fails the test
(the condition is false).
IF Statements
Choose from ten different test conditions, or
IF
statements, when setting tests for phases
1 through 5.
IF Statement Description
Skip Test Selects the
TRUE
statement. The
FALSE
statement is
ignored.
IF Target Capacity Met Selects the
TRUE
statement if the capacity during the last
discharge cycle meets the target capacity; otherwise,
selects the
FALSE
statement.
IF Target Capacity Not Met Selects the
TRUE
statement if the capacity during the last
discharge is below the target capacity; otherwise, selects
the FALSE statement.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cadex Electronic C7000-C Series and is the answer not in the manual?

Cadex Electronic C7000-C Series Specifications

General IconGeneral
BrandCadex Electronic
ModelC7000-C Series
CategoryMeasuring Instruments
LanguageEnglish