Cadex Electronics Inc. C7000-C Series Battery Analyzers .
Saving program and target capacity is useful if there are several Cadex analyzers and a
unit is dedicated to one specific program or target capacity.
To set the method of saving changes to program and target capacity
1.
From the global display, press
MENU
.
2.
Press 5 or 6 to scroll to
OPTION CONTROLS
and then press
ENTER
.
3. Press
5
or
6
to scroll to PROGRAM/TARGET CHANGES and then press ENTER.
4. Press
5
or
6
to scroll to the required setting:
C-C
ODE
(default) saves any changes made to the program settings or the target capacity
to the active C-Code.
STATION
saves any changes made to the program settings or the target capacity to the
battery station. These changes override any settings in the active C-Code.
5. Press ENTER.
6. Press
5
or
6
to scroll to YES to accept changes and press ENTER.
7.
Press
ESC
twice to return to the global display.
Note To use all of the settings from the active C-Code, this option must be set to C-
C
ODE
. Setting it to C-C
ODE
will erase all settings saved to the stations.
Resuming Service After Power Failure
If there is a power failure, the back-up memory in the analyzer keeps service data for one
hour. If the power failure lasts less than an hour, battery service resumes from where it
left off. If the power failure lasts longer than one hour, the battery resumes from the
beginning. This time can be modified:
To change the Power Failure Resume Hours
1.
From the global display, press
MENU
.
2.
Press 5 or 6 to scroll to
SYSTEM SETUP
, press
ENTER
.
3.
Press 5 or 6 to scroll to
POWER FAILURE RESUME HOURS
, press