Cadex Electronics Inc. C7000-C Series Battery Analyzers .
Program
Does this
Is used for this
Prime
Repeatedly cycles battery until
maximum capacity is reached.
If capacity improvement is
more than 5% over previous
reading, an additional cycle is
applied.
• Preparing new batteries for field
use.
• Conditioning batteries that have
been in storage.
QuickSort
Estimates battery capacity
using an inference algorithm.
Can be used for single cell Li-
Ion, 3.6V, 500 – 1500mAh
16K Battery Adapters only
(adapters are identified with a
“16K” sticker on the back)
• To rapidly sort batteries.
• A ‘universal’ rapid test for Li-Ion
batteries.
• Can be used with the Flex Arm
adapter (07-110-0180)
Auto
Function: Exercises batteries to maintain optimum performance. This is the recommended
program for routine maintenance of batteries. It reconditions NiCd and NiMH batteries that
do not reach Target Capacity. Li-ion and SLA batteries are not reconditioned, only
exercised. Batteries in use are typically cycled every three months on Auto. If batteries are
failing prematurely, increase the frequency of service on the Auto program.
Sequence: The battery is first cycled (charged and then discharged) to determine it’s true
capacity. If NiCd and NiMH batteries do not meet the target capacity at the end of the
discharge cycle, they are reconditioned to reduce battery memory. Following recondition,
the battery is cycled again to determine the recovered or final capacity. The battery is fully
charged when the program completes.
SLA and Li-ion batteries are cycled once. If the target capacity is not reached in the first
cycle, it is cycled again. Recondition is not performed for Li-ion and SLA batteries.
Results: Global display shows battery capacity as a percentage of manufacturers stated
capacity for the battery model. Detailed display shows average battery or cell voltage,
analyzer charge or discharge current in mA, OhmTest results, battery temperature (if
applicable), and duration of service