Cadex Electronics Inc. C7000-C Series Battery Analyzers .
76
BATTERY SERVICE REPORT
Company: CADEX ELECTRONICS
Date: 01/19/2000
Time: 16:47:11
BATTERY STATUS
Battery: STATION 2
Battery ID: 1234567890
Current Cycle: PROCESS COMPLETE
Cycle Capacities: 30% 82% 98%
Battery Resistance: 122m
Cell Voltage: 3.91V/cell
Charge Cycles: 3
Discharge Cycles: 3
Recondition Cycles: 0
Elapsed Time: 0 Days 6 Hours 40 Minutes
BATTERY PARAMETERS
Battery C-Code: 40-02-016:0505-505-3407
Program: Auto
Target Capacity: 80%
Battery Type:
42 - Lithium Ion
Number of Cells: 2 (7.2V)
Battery Rating: 400mAh
Charge Rate: 0.50C ( 200mA) Max. Charge Voltage:
4.10V/Cell
Discharge Rate: 0.50C ( 200mA) End Discharge: 4.10V/Cell
End of Charge: 0.10C ( 40mA) Max. Standby Voltage:
4.05V/Cell
Capacity Offset: 0% Temperature Sensing: 5
o
C - 45
o
C
FAULT CODES
FINAL STATUS
Ready
Figure 6: Battery service report