Chapter 6
6-11
To view the service call history, select SERVICE MODE > DISPLAY > ERROR.
6.1.4.2 E141-4046 Recovery system rotation count reached 50,000.
0012-9542
iPF6000
<Cause>
The machine detected that the rotation count of the purge unit reached the specified value.
<Probable fault location>
Purge unit or main controller PCB
<Countermeasure>
1. Replace Purge unit.
After replacing the purge unit, select [SEVICE MODE]>[INITIALIZE]>[PARTS COUNTER] to reset the counter.
2. Replace main controller PCB.
6.1.4.3 E144-4047 Supply system's count error
0012-9545
iPF6000
<Cause>
The machine detected that the carriage scan count reached the specified value.
<Probable fault location>
Ink tank or main controller PCB
<Countermeasure>
1. Replace the ink tank unit.
After replacing the ink tank unit select [SEVIVE MODE]>[INITIALIZE]>[PARTS COUNTER] to reset the counter.
2. Replace the main controller PCB.
6.1.4.4 E146-4001 Borderless/idle ejection/mist collection count full
0012-9557
iPF6000
<Cause>
The machine detected that the waste ink box, the mist fan unit or platen duct became full of ink.
<Probable fault location>
Waste ink box, mist fan unit, platen duct or main controller PCB
<Countermeasure>
1. Replace the waste ink box, mist fan unit or platen duct.
After replacing the waste ink box, mist fan unit or platen duct, select[SEVICE MODE]>[INITIALIZE]>[PARTS COUNTER] to reset the counter.
2. Replace main controller PCB.
6.1.4.5 E194-404A Non-discharge detection count error
0012-9560
iPF6000
<Cause>
The machine detected that the Non-discharge count error
<Probable fault location>
Head management sensor or main controller PCB
<Countermeasure>
1. Replace the head management sensor.
After replacing the head management sensor, select [SERVICE MODE]>[INITIALIZE]>[PARTS COUNTER] to reset the counter.
2. Replace the main controller PCB.
6.1.4.6 E196-4040/E196-4041/E196-4042/E196-4045/E196-4049 main controller PCB error
0012-9564
iPF6000
<Cause>
The main controller PCB is defective.
<Probable fault location>
Firmware or main controller PCB
<Countermeasure>
1. Upgrade the firmware.
2. Replace the main controller PCB.
6.1.4.7 E198-401C/E198-401D/E198-401E RTC error
0012-9599
iPF6000
<Cause>
The RTC of the main controller is not found.