8.3.3 Errors
0024-9331
iPF6300 / iPF6350 / iPF6300S
* Codes represent the numbers that are displayed in DISPLAY in service mode.
If the same message is displayed when the printer is turned off, then back on, take action as recommended in the Action column.
T-8-7
Display massage Code* Condition detected Action
Problem with Printhead
Chk printing results
01800500-1010 The number of the printhead's non-discharge nozzle
was over fixed level during the non-discharge
detection operation.
Clean the printhead.
Replace the printhead.
Problem with Printhead R
Chk printing results
01800500-1012 The number of the right printhead's non-discharge
nozzle was over fixed level during the non-discharge
detection operation.
Clean the printhead.
Replace the right printhead.
Problem with Printhead L
Chk printing results
01800500-1013 The number of the left printhead's non-discharge
nozzle was over fixed level during the non-discharge
detection operation.
Clean the printhead.
Replace the left printhead.
Move the blue platen switch
No.02 to the right.
01861007-1056 The platen shutter switch No.2 has been closing when
shutter is the mode of opening.
Check the opening or closing of the platen shutter
switch.
Check the platen and multi sensor and surrounding
parts.
Replace the multi sensor.
Move the blue platen switch
No.03 to the right.
01861008-1057 The platen shutter switch No.3 has been closing when
shutter is the mode of opening.
Check the opening or closing of the platen shutter
switch.
Check the platen and multi sensor and surrounding
parts.
Replace the multi sensor.
Move the blue platen switch
No.04 to the right.
01861009-1058 The platen shutter switch No.4 has been closing when
shutter is the mode of opening.
Check the opening or closing of the platen shutter
switch.
Check the platen and multi sensor and surrounding
parts.
Replace the multi sensor.
Move the blue platen switch
No.05 to the right.
0186100A-1059 The platen shutter switch No.5 has been closing when
shutter is the mode of opening.
Check the opening or closing of the platen shutter
switch.
Check the platen and multi sensor and surrounding
parts.
Replace the multi sensor.
Move the blue platen switch
No.06 to the right.
0186100B-105A The platen shutter switch No.6 has been closing when
shutter is the mode of opening.
Check the opening or closing of the platen shutter
switch.
Check the platen and multi sensor and surrounding
parts.
Replace the multi sensor.
Move the blue platen switch
No.07 to the right.
0186100C-105B The platen shutter switch No.7 has been closing when
shutter is the mode of opening.
Check the opening or closing of the platen shutter
switch.
Check the platen and multi sensor and surrounding
parts.
Replace the multi sensor.
Move the blue platen switch
No.08 to the right.
0186100D-105C The platen shutter switch No.8 has been closing when
shutter is the mode of opening.
Check the opening or closing of the platen shutter
switch.
Check the platen and multi sensor and surrounding
parts.
Replace the multi sensor.
Move the blue platen switch
No.09 to the right.
0186100E-105D The platen shutter switch No.9 has been closing when
shutter is the mode of opening.
Check the opening or closing of the platen shutter
switch.
Check the platen and multi sensor and surrounding
parts.
Replace the multi sensor.
Move the blue platen switch
No.10 to the right.
0186100F-105E The platen shutter switch No.10 has been closing
when shutter is the mode of opening.
Check the opening or closing of the platen shutter
switch.
Check the platen and multi sensor and surrounding
parts.
Replace the multi sensor.
Move the blue platen switch
No.11 to the right.
01861010-105F The platen shutter switch No.11 has been closing
when shutter is the mode of opening.
Check the opening or closing of the platen shutter
switch.
Check the platen and multi sensor and surrounding
parts.
Replace the multi sensor.
Move the blue platen switch
No.12 to the right.
01861011-1060 The platen shutter switch No.12 has been closing
when shutter is the mode of opening.
Check the opening or closing of the platen shutter
switch.
Check the platen and multi sensor and surrounding
parts.
Replace the multi sensor.
Move the blue platen switch
No.13 to the right.
01861012-1061 The platen shutter switch No.13 has been closing
when shutter is the mode of opening.
Check the opening or closing of the platen shutter
switch.
Check the platen and multi sensor and surrounding
parts.
Replace the multi sensor.
Move the blue platen switch
No.14 to the right.
01861013-1062 The platen shutter switch No.14 has been closing
when shutter is the mode of opening.
Check the opening or closing of the platen shutter
switch.
Check the platen and multi sensor and surrounding
parts.
Replace the multi sensor.
Paper size not detected.
Reload paper.
03010000-200A Unable to detect the paper width (Paper loaded at an
improper position)
Reload the paper