7-MAINTENANCE
Every2000hours
Enginecoolant
NOTICE:NEVERmixOATcoolantwithconventionalcoolant.Undernocircumstancesshouldyoutopoffacooling
systemwithonlywater.Youcanusearefractometertochecktheconcentrationlevel.SupplementalCoolantAdditives
(SCA)shouldnotbeusedwhenusingCASEAKCELAACTIFULL™OTEXTENDEDLIFECOOLANT.
1.Movethemachinetoalevelandrmground.
2.Raisetheloaderattachmentandinstallthesafetysup-
portstrut.
3.Placethebackhoeattachmentintheroadtravelposi-
tion.
4.Placethedirection-of-travelleverandgearshiftleverin
neutralposition.
5.Immobilizethemachinewiththeparkingbrake.
6.Stoptheengineandremovethestarterswitchkey.
7.Openandraisetheengineguard.
MOLI12LBB0446AA1
Draining
WARNING
Burnhazard!
Hotcoolantcansprayandscaldifyouremovetheradiatorordeaerationtankcapwhilethesystem
ishot.Toremovethecap:allowthesystemtocool,turnthecaptotherstnotch,andwaitforall
pressuretorelease.Removethecaponlyafterallpressurehasreleased.
Failuretocomplycouldresultindeathorseriousinjury.
W0367A
1.Placeacontainerwithsufcientcapacityunderthera-
diatordraincock.
2.Unscrewandremovethecap(2)fromthereservoir(1).
LEEN12T0877FA2
3.Placeacontainerundertheradiator.
4.Installadrainhoseabout1m(3.2ft)onthedraincock
(3)andputtheotherendofthehoseintoacontainer.
5.Opentheradiatordraincock(3)andallowthecoolant
toowout.
NOTE:Properlydisposeofuidaccordingtolocalandna-
tionalregulations.