OPERATING INSTRUCTIONS
105
RIGHT PAGE
Bur 6-34090EUR
7. Test the parking brakes at a maximum of 250 hour intervals:
A. Apply the parking brake by pushing down on the top of the switch.
B. Shift the transmission into 3rd gear NEUTRAL.
C. Press the program switch.
D. Press the up count switch until the Display Center reads 011.
E. Return the program/reset switch to the off (center) position.
F. Press the up count switch until the 01 is shown in the Display Center.
G. Push down and hold your foot against the brake pedal.
H. Enable the pilot control levers by pushing down on the right hand side of
the pilot control switch.
I. Raise the loader bucket above the ground.
J. Shift the transmission to FORWARD and increase the engine speed to full
throttle. The machine must not move. If the machine does move, see the
service manual or see your dealer and correct the problem.
K. Shift the transmission to REVERSE and increase the engine speed to full
throttle. The machine must not move. If the machine does move, see the
service manual or see your dealer and correct the problem.
L. Shift the transmission to the NEUTRAL position.
M.Press the reset switch momentarily to return to normal operation.
CM112
M142A
M122B
SB013
8. Release the parking brake.
9. Test the foot brakes for correct operation at a maximum of 250 hour intervals.
A. Push down and hold your foot against the brake pedal.
B. Raise the loader bucket just above the ground.
WARNING: DO NOT operate the machine while under the influence of
alcohol or drugs.
WARNING: Never operate the engine in a closed building. Proper
ventilation is required under all circumstances.
WARNING: Operate the machine with the door closed to provide proper
ROPS protection and to properly utilize the heating, ventilating or cooling
systems.
WARNING: Hillside operations can be dangerous. Rain, snow, ice, loose
gravel, soft ground, etc., change the ground conditions. You must make a
judgment if your machine can be safely operated on any hillside or ramp.