FIRE EXTINGUISHER MOUNTING (If Equipped)
Type of Fire Extinguisher
It is recommended that you have a fire
extinguisher on your machine. The fire
extinguisher shown below is available
from your dealer and can be installed
on the machine.
This dry chemical fire extinguisher has
a 5 pound capacity and is approved for
Class A, B and C type fires. The
operating temperature is from -65° to
120°F (-54° to 49°C).
Inspection and Care
EVERY MONTH - It is recommended
that you inspect the fire extinguisher
once each month for damage and to
insure that the gauge is working
correctly.
EVERY 6 MONTHS - Have the dry
chemical removed and refilled by a fire
equipment technician.
ONCE EACH YEAR - Have the fire
equipment technician inspect the fire
extinguisher.
153L95
IMPORTANT: DO NOT mount the Fire Extinguisher on any part of the ROPS or
FOPS structure. DO NOT make any modifications to the ROPS or FOPS
structure.