INSTRUMENTS/CONTROLS
48
LEFT PAGE
Bur 6-34090EUR
INSTRUMENT PANEL INDICATORS
BD02B020
17. VOLT METER GAUGE:
The volt meter gauge indicates the condition of the batteries and
charging system. The amount of voltage is shown with indicator bars.
Normal operating range is in the green zone. When the voltage
increases or decreases the bars move into the yellow zone and begin
to flash, the warning alarm sounds for three seconds, and the caution master
indicator turns yellow.
NOTE: Stop the machine and correct the problem.
VOLTMETER GAUGE
Gauge Indication Engine Speed Condition of charging
system
Master
Indicato
r
Gauge
Status
Alarm
Status
0 to 18 Volts Stopped or low
idle
Very low battery charge Caution
(Yellow)
Flashes 3 Seconds
18 to 24 Volts
Stopped or low
idle
Low to normal battery
charge
Above low idle Problem in charging
system
24 to 26 Volts
Stopped or
low idle
Normal battery charge
Above low idle Problem in charging
system
26 to 32 Volts Above low idle Normal operating range
32 Volts and above
(See the note below.)
Problem in charging
system (overcharging)
Caution
(Yellow)
Flashes 3 Seconds
17
BS98M032