EasyManuals Logo

Chroma 63800 Series User Manual

Chroma 63800 Series
198 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #177 background imageLoading...
Page #177 background image
Status Reporting
9-3
Query Syntax : STATus:QUEStionable:EVENt?
Parameters : none
Return Parameters : <NR1>
STATus:QUEStionable:CONDition?
Description : This query is the value of the Questionable Condition
register. This register is a read-only register, which holds the real time (unlatched)
Questionable status of the AC load.
Query Syntax : STATus: QUEStionable:CONDition?
Parameters : none
Return Parameters : <NR1>
STATus:QUEStionable:ENABle
Description : This command set and read the value of the Questionable
Enable register. The register is a mask for enabling specific bits from the Questionable Enable
register to set the Questionable summary bit (QUES) of the Status Byte register (STB). The
Questionable summary bit is the logical OR of all enabled Questionable Event register bit.
Query Syntax : STATus: QUEStionable:ENABle?
Parameters : <NR1>, 0 ~ 255
Return Parameters : <NR1> (Register value)
STATus:
OPERation:
EVENt Returns the value of the event register
CONDition Returns the value of the condition register
ENABle Enable specific bits in the Event register
STATus:OPERation:EVENt?
Description : This query is the value of the Operation Event register. The
Event register is a read-only register, which holds all events. Reading the Operation Event
register and clears it.
Query Syntax : STATus:Operation:EVENt?
Return Parameters : <NR1>
STATus:OPERation:CONDition?
Description : This query is the value of the Operation Condition register.
This register is a read-only register, which holds the real time (unlatched) Operation status of
the AC load.
Query Syntax : STATus:Operation:CONDition?
Return Parameters : <NR1>
STATus:OPERation:ENABle
Description : This command set and read the value of the Operation
Enable register. The register is a mask for enabling specific bits from the Operation Enable
register to set the Operation summary bit (OPER) of the Status Byte register (STB). The
Operation summary bit is the logical OR of all enabled Operation Event register bit.
Query Syntax : STATus: QUEStionable:ENABle?
Parameters : <NR1>, 0 ~ 255
Return Parameters : <NR1> (Register value)