ABOUT TAB
This tab contains information about the camera hardware, software, and current operating conditions. In
the event that support from Kron Technologies is required, it is useful to provide a photo of this screen
along with the rest of the inquiry if possible.
The lower left-hand side of the display shows live information pertaining to the camera’s internal systems.
The table below describes these parameters in more detail.
Label
Description
Sensor
Temperature
The surface temperature of the image sensor inside the camera. Typical values
at room temperature are between 40 and 55 degrees Celsius.
System
Temperature
The internal temperature at a more central point inside the camera. This value
typically equalizes close to that of the Sensor Temperature.
Battery
Voltage
The current battery voltage. This value depends on the condition of the battery
and the charge and can be helpful in determining whether a battery can no
longer function properly.
Last Shutdown
Reason
The reason for the last shutdown that had occurred. Each tag separated by a
comma signifies a stage in the shutdown sequence that was acknowledged.