151
The tables below list reader settings as well as symbology settings for the Laser (SE955)
scan engine.
READER SETTINGS TABLE
Laser Engine Description Default
Decode Time-out Set the maximum time for decoding to continue during a
scan attempt.
1~9 (second)
3 sec.
Redundancy Level Level 1
Level 1 Following barcodes must be successfully read twice before being decoded:
Barcode Types Code Length
Codabar All
MSI 4 characters or less
Industrial 25 (Discrete 25) 8 characters or less
Interleaved 25 8 characters or less
Level 2 All barcodes must be successfully read twice before being decoded.
Level 3 All barcodes except for the following barcodes must be successfully read
twice before being decoded. Following barcodes must be read three times:
Barcode Types “Excluded” Code Length
MSI 4 characters or less
Industrial 25 (Discrete 25) 8 characters or less
Interleaved 25 8 characters or less
Level 4
All barcodes must be successfully read three times before being decoded.
Scan Angle Select the scan angle for Long Range Laser scan engine.
“narrow” for 35°
“wide” for 47°
Wide
Scan Mode Laser mode
Continuous Mode Non-stop scanning
To decode the same barcode repeatedly, move away the scan beam
and target it at the barcode for each scanning.
Laser Mode Hold down the scan trigger to start with scanning.
The scanning won’t stop until (a) a barcode is read, (b) the preset
timeout expires, or (c) you release the trigger.