164
CP30 Mobile Computer
Reference Manual
ISBT Concatenation
Redundancy
When “Auto-discriminate” is applied, decide the
concatenation redundancy (2~20 times).
10 times
Industrial 25 (Discrete 25) Enable
Select Length
(min/max)
One or two fixed lengths
Range (1~55)
4~55
Interleaved 25 Enable
Convert to EAN-13 Convert a 14-character barcode into EAN-13 if the
following requirements are met:
The barcode must have a leading 0 and a valid EAN-13
check digit.
“Check digit verification” must be disabled.
No
Check digit verification Decide whether to verify the check digit. If desired, select
one of the algorithms below. If the check digit is incorrect,
the barcode will not be accepted.
Disable
USS check digit
OPCC check digit
Disable
Transmit Check Digit Decide whether to include the check digit in the data being
transmitted.
No
Select Length
(min/max)
One or two fixed lengths
Range (1~55)
4~55
Matrix 25 Enable
Redundancy Decide whether to enable decode redundancy. No
Check digit verification Decide whether to verify the check digit. If the check digit
is incorrect, the barcode will not be accepted.
No
Transmit Check Digit Decide whether to include the check digit in the data being
transmitted.
No
Select Length
(min/max)
One or two fixed lengths
Range (1~55)
4~55
Chinese 25 Enable
Code 39 Enable
Convert to Code 32 Convert to Italian Pharmacode. No
Code 32 Prefix Prefix character “A” to Code 32 barcodes. No
Check digit verification Decide whether to verify the check digit. If the check digit
is incorrect, the barcode will not be accepted.
No
Transmit Check Digit Decide whether to include the check digit in the data being
transmitted.
“Check digit verification” must be enabled.
No
Code 39 Full ASCII Code 39 Full ASCII includes all the alphanumeric and
special characters.
No