9-10
Cisco SCE8000 GBE Installation and Configuration Guide
OL-19897-02
Chapter 9 Removal and Replacement Procedures
Removing and Replacing the Power Supply
Figure 9-5 DC-Input Front Panel for 2700-W DC-Input Power Supply
Step 6
Attach the appropriate lugs to the DC-input wires and ground wire. The wires should be sized according
to local and national installation requirements. Use only copper wire. The maximum width of a lug is
0.600 inch (15.2 mm).
Note Use fine-stranded copper conductors rated for 90-degrees Celsius for North American installations.
Note The power supply terminal block lug opening width is 0.62 inch (15.8 mm). The terminal posts are
centered 0.625 inches (15.88 mm) apart and are 1/4-20 threaded. We recommend that you use an
appropriately sized industry standard 2-hole, standard barrel compression lug. The power supply ground
studs, located below the terminal block, are also threaded 1/4-20 and require two 1/4-inch split-ring
washers and two 1/4-20 hex nuts.
Table 9-1 Terminal Block Connections
1 Captive installation
screw
7 Cable holder cover
2 DC power cable
terminal block
8 Cable holder
3Status LEDs9Tie-wrap
4 DC power cable
terminal block cover
10 Cable holder
5 Cable holder cover 11 Tie-wrap
6 Ground
132219
PW
R-2700-DC/4
-VE-1
-VE-1
-VE-2
-VE-2
IN
PU
T1
O
K
48V
-60V
=40A
IN
P
U
T2
O
K
48V
-60V
=40A
FA
N
O
K
O
U
TP
U
T
FA
I
L
ALL FASTENERS M
UST BE F
ULL
Y ENG
AGED
PRIO
R TO OPERATING THE PO
W
ER SUPPLY
3
2
6
4
10
1
8
5
7
11
9

Table of Contents

Related product manuals