User Guide| LQ Series 4.0
l An LQ/HelixNet Link-Group supports up to three linked HelixNet Main Stations
and up to three linked LQ units (a maximum of 6 devices in total).
14.3.1
General outline: create a HelixNet/LQ Link-Group
1. Access the CCM of the HMS. Make sure the device Link-Group Role is set to
Link-Master. Default setting: Disabled.
2. Access the CCM of the LQ unit. Make sure the device Link-Group Role is set to
Link-Member. Default setting: Link-Master.
3. Give the LQ Link-Member device the IP address of the HelixNet Link Master.
Repeat this step for each device to be linked to the Link-Master.
4. Once you have linked the members to the master, all devices in the Link-Group
will be visible in the Overview page of the CCM.
5. Navigate to the Assignments page of any device in the Link-Group to view and
configure available ports.
14.3.2
Demonstration: create a HelixNet/LQ Link-Group
1. Ensure the HelixNet device is set to Link-Master in the CCM of the Main Station.
Navigate to Device > Linking > Link-Group Role.
Page 126