User Guide| LQ Series 4.0
Equipment Port settings
Encore RS beltpack 701/2/3
Power: Enabled Termination: Enabled
Auto-nulling: Start auto-nulling
Encore MS-702/4Encore PK-7Encore
PS-702/4
Power: Disabled Termination:
DisabledAuto-nulling: Start auto-nulling
17.2 Connecting to 4-wire equipment
To minimize noise, use screened (shielded) cable when connecting 4-wire ports.
17.2.1 Pin-out configuration
Pin-out configuration can be set on LQ Series 4-wire interfaces (not 4W + GPIO).
This is a software switch that switches the configuration of the pins on the RJ45
etherCON connectors, according to the device you are connecting to. See
Interconnection Guidelines.
Pin-out configuration is set ‘to Matrix’ by default. To set the pin configuration of a
device:
1. Access the CCM for any unit in the Link-Group.
2. Navigate to Device > Ports .
3. Select either ‘to Matrix’ or ‘to Panel’.
Page 144