LPOD Outdoor Amplifier / Block Up Converter (BUC) Revision 9
Serial-based Remote Product Management MN-LPOD
5–15
Parameter Type
Description of Arguments
(Note that all arguments are printable ASCII characters)
Response to Query
(Target to
Controller)
Sets or returns, as a reference point, the value of the LNB Current Supply (in mA) in the form xxx.x.
Default value: 000.0
The LNB current alarm point is then determined by the calibrated LNB reference point, and the LNB current window
setting (see LCW command).
Note: this command will return a mode error if the LNB current source output has not been enabled first (see
LCS command).
Example: <1/CLC=’cr’
>0001/CLC=’cr’’lf’
The CLC query will return the value that was stored during the LNB current calibration.
Example: <1/CLC?’cr’
>0001/CLC=xxx.x where xxx.x is the calibrated LNB current value in mA.
(See Description of
Arguments)
Clears the statistics log entries. This command takes no arguments.
Example:
<1/CSL=1’cr’
Returns the Maintenance status of the unit, response is semicolon delimited, in the form aaaa;bbbbb;ccc where:
aaaa = Remote Unit Address
bbbbb = Remote Baud Rate
ccc = Reference oscillator tuning voltage DAC value (see Note)
Note: ccc is only present if a reference oscillator is installed.
Example:
<1/CUS?’cr’
>0001/CUS=aaaa;bbbbb;ccc;’cr’’lf’
(See Description of
Arguments)