LPOD Outdoor Amplifier / Block Up Converter (BUC) Revision 9
Serial-based Remote Product Management MN-LPOD
5–16
Parameter Type
This is the concise version of the RMS command. Returns the Maintenance status of the unit, response is
semicolon delimited, in the form aaa.a;bbb.b;ccc.c;ddd.d;eee.e;fff.f;ggg.g;hhh.h;iii.i;jjj.j;kkk.k;lll.l;mmm.m;nnn.n;
ooo.o;ppp.p;qqq.q;rrr.r;sss.s;ttt.t where:
aaa.a = P24V1
bbb.b = P24V2
ccc.c = LNBVT (see Note)
ddd.d = P13VT
eee.e=P10V1
fff.f = A10V1
ggg.g = A10V2 (see Note)
hhh.h = P7V8T
iii.i = P5V8T
jjj.j = P2V5T
kkk.k = P1V2T
lll.l = N5V8T
mmm.m = FANR1 (see Note)
nnn.n = FANR2 (see Note)
ooo.o = BUCVT (see Note)
ppp.p = FWPWR
qqq.q = REFVT (see Note)
rrr.r = LNBCS (see Note)
sss.s = ATEMP
ttt.t = OTEMP (see Note)
Note: ccc.c, ggg.g, mmm.m, nnn.n, ooo.o, qqq.q, rrr.r, and ttt.t will appear if the appropriate model/options have
been selected/installed. Otherwise, the unused fields will display XXXXX.
Example: <1/CMS?
>0001/CMS=aaa.a;bbb.b;ccc.c;ddd.d;eee.e;fff.f;ggg.g;hhh.h;iii.i;jjj.j;kkk.k;lll.l;mmm.m;nnn.n;ooo.o;ppp.p;qqq.q;
Sets or returns the LNB current window alarm in the form x, where:
0=Disabled (default value)
1=Enabled (see Note)
Note: If disabled, the LCW value will be retained, but unused.
Example: <1/CWE=0’cr’