LPOD Outdoor Amplifier / Block Up Converter (BUC) Revision 9
Serial-based Remote Product Management MN-LPOD
5–22
Parameter Type
Sets or returns Local or Remote state for Indoor SSPA (always in remote mode for Outdoor SSPA) in the form x,
where x=0, 1, 2, or 3::
0 = Local
1=Serial
2=Ethernet
3=Serial+Ethernet (default value)
Note: The user will always have query access in any mode. The LRS command is also available in all modes as
a means of acquiring control. The intent of this command is to limit changes from being made on multiple
interfaces at the same time. Units without a front panel will treat an entry of 0 as reserved, and will refuse the
command by returning a mode error. The web page GUI will refuse connections unless LRS is set to enable
Ethernet remote control.
Example: <1/LRS=3’cr’
>0001/LRS=’cr’’lf’
Returns the MAC address of the unit, in hexadecimal format xx-xx-xx-xx-xx-xx
Example: <1/MAC?’cr’
>0001/MAC=00-06-B0-00-D2-A7’cr’’lf’