Returns the maximum operating point of the unit along with its timestamp
Reply format:
MAXFET=sYYYC mmddyy hhmmss’cr’
MINFET=sYYYC mmddyy hhmmss’cr’
MAXPFT=sYYYC mmddyy hhmmss’cr’
MAXDTP=sYYYC mmddyy hhmmss’cr’
MAXHTS=sYYYC mmddyy hhmmss’cr’
MINHTS=sYYYC mmddyy hhmmss’cr’
MAXOST=sYYYC mmddyy hhmmss’cr’
MAXRFP=sZZ.ZZ mmddyy hhmmss’cr’
MINRFP=sZZ.ZZ mmddyy hhmmss’cr’
Where:
sYYYC is the temperature
sZZ.ZZ is the power
Note: not all LPODs have outside temperature monitor. In that case, MAXOST and MINOST will report XXXXX
XXXXXX XXXXXX
Example: <1/MOP?’cr’
>0001/mop=’cr’
MAXFET=+000C 010208 180729’cr’
MINFET=+000C 010208 180729’cr’
MAXPFT=+000C 010208 180659’cr’
MAXDTP=+000C 010208 180729’cr’
MAXHTS=+050C 010208 180729’cr’
MINHTS=+050C 010208 180729’cr’
MAXOST=XXXXX XXXXXX XXXXXX’cr’
MINOST=XXXXX XXXXXX XXXXXX’cr’
MAXRFP=+00.00 010208 180659’cr’
MINRFP=+00.00 010208 180659’cr’