Parameter Type
Description of Arguments
(Note that all arguments are printable ASCII characters)
Response to Query
(Target to
Controller)
Sets or returns the SNMP System Location string
Example: <1/SSL=Upstairs back right.
Note: If not configured it returns empty string. <1/SSL=
(see Description of
Arguments)
Sets or returns the SNMP System Name string
Example: <1/SSN=Remote1.
Note: If not configured it returns empty string. <1/SSC=
(see Description of
Arguments)
Sets or returns the IP address of the first SNMP Trap destination IP Address 1 where traps will be sent, in the
form xxx.xxx.xxx.xxx
Example: <1/STA=010.006.030.001
Note: When not configured, returns >0001/STA=0.0.0.0
(see Description of
Arguments)
Sets or returns the IP address of the first SNMP Trap destination IP Address 2 where traps will be sent, in the
form xxx.xxx.xxx.xxx
Example: <1/STB=010.006.030.001
Note: When not configured, returns >0001/STB=0.0.0.0
(see Description of
Arguments)
Sets or returns the SNMP Trap Version that will be used to send traps.
1=SNMP Trap Version 1
2=SNMP Trap Version 2
Example: <1/STV=0
(see Description of
Arguments)
Sets or returns the SNMP write community string. Empty string is not allowed
(see Description of
Arguments)
Returns the value of the internal software revision installed in the unit, in the form:
Boot:x.y.z Bulk1:x.y.z Bulk2:x.y.z
-or-
Boot:x.y.zz Bulk1:x.y.zz Bulk2:x.y.zz
Bulk1:x.y.zz
Bulk2:x.y.zz