LPOD Outdoor Amplifier / Block Up Converter (BUC) Revision 9
Serial-based Remote Product Management MN-LPOD
5–35
Parameter Type
Description of Arguments
(Note that all arguments are printable ASCII characters)
Response to Query
(Target to
Controller)
Sets or returns the real-time clock time, from midnight, in the form hhmmss, where:
hh = hours, from 00 to 23
mm = minutes, from 00 to 59
ss = seconds, from 00 to 59
Example (time = 23 hours, 12 minutes and 59 seconds since midnight): <1/TIM=231259’cr’
>0001/TIM=’cr’’lf’
(See Description of
Arguments)
Returns the temperatures of the Heatsink in the form of sxxxx, where:
s = sign (+) or (-)
xxxx = temperature.
Example: <1/TMP=+26.0
(See Description of
Arguments)
Returns the number of stored alarms that remain unread in the alarm log, in the form xx. A maximum of 255
events may be stored in the alarm log. Numbers over 99 are reported as 99.
Example reply: <1/TNA? ’cr’
>0001/TNA=14’cr’’lf’
(See Description of
Arguments)
Returns the number of stored events that remain unread in the events logs, in the form xx.
Example: <1/TNE? ’cr’
(See Description of
Arguments)
Sets or returns the Time Protocol setting in the form x, where:
0 = Time protocol disabled
1 = Time protocol enabled
Example (Time protocol enabled): <1/TPE=1’cr’
(See Description of
Arguments)
Sets or returns the Time Server IP address for the Unit Tx Ethernet management port, in the form
xxx.xxx.xxx.xxx
Default value: 255.255.255.255
Example: <1/TPS=192.168.001.005
xx.xxx.xxx.xxx.yy
(See Description of
Arguments)