EasyManua.ls Logo

Crystal Instruments Spider - Page 147

Default Icon
426 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Spider DSA User’s Manual
147
when test just finished
when average number is reached
save 3D signals when test aborts
every___seconds
Frame Number: the results of the given number of frames
when limit is exceeded
when triggered
Enable a timer when continue after trigger: save with the timer
enabled after a run is triggered to start
Options only available in Sine reduction:
Software saves the results
when sweeping direction changes
When the software saves results to PC, results include
Signals
Screenshot of the active signal window
Screenshots of all signal windows
Screenshots of the software
In the File name options area, Record and Save file name prefixes may be
defined separately and differentiated.
By checking the box,Allow specify file name and save location before
manually click save”, when the user click Save button to manually save signals,
the EDM will ask for the file name and location before the signals are saved.
Figure 104. File Name and Location for Saved Signals

Table of Contents