Spider DSA User’s Manual
299
clicking on the Add button. The added signals list is shown at the left side of the
pane. Unnecessary signals can be removed using the “Delete” button.
It must be noted that the Order Value can take a maximum value as specified in
the Order Analysis settings and must be within the resolution selected in the
Order Analysis settings. For e.g. with Max Order setting of 10 and a Delta Order
setting of 0.5, an order with a value more than 10 or an order value which is not a
integer multiple of 0.5 cannot be entered.
Figure 206: Adding complex order track signals
When all the required signals are added, click on “OK” to create all the signals that
are configured by this pane.
This pane can be opened multiple times to add or modify the Order Tracks. Once
the signals are added, they appear in the Measured Signals setup window under
the Order Tracks tab as shown: