Enter/Exit Programming Mode 1D Symbologies
154
Gryphon™ GPS4400
GS1 DataBar™ Expanded Set Length 1
This feature specifies one of the bar code lengths for GS1 DataBar™ Expanded
Length Control. Length 1 is the minimum label length if in Variable Length
Mode, or the first fixed length if in Fixed Length Mode. Length includes the
bar code’s data characters only. The length can be set from 1 to 74 charac-
ters
.
Table 17 provides some examples for setting Length 1. See page
241 for
detailed instructions on setting t
his feature.
Table 17. GS1 DataBar™ Expanded Length 1 Setting Examples
STEP ACTION EXAMPLES
1 Desired Setting
01 Character 07 Characters 52 Characters 74 Characters
2 Scan ENTER/EXIT PROGRAMMING MODE
3 Scan SELECT GS1 DataBar™ EXPANDED LENGTH 1SETTING
4
Scan Two Characters From
Appendix D, Keypad
‘0’ and ‘1’ ‘0’ and ‘7’ ‘5’ and ‘2’ ‘7’ AND ‘4’
5 Scan ENTER/EXIT PROGRAMMING MODE
Select GS1 DataBar™ Expanded Set Length 1 Setting
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start again
at the beginning.
CANCEL
DEFAULT
01 = Length 1 is 1 Character