EasyManuals Logo

Datalogic Gryphon GPS4421 User Manual

Datalogic Gryphon GPS4421
316 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #195 background imageLoading...
Page #195 background image
2D Symbologies Enter/Exit Programming Mode
Product Reference Guide
185
Maxicode Length Control
This feature specifies either variable length decoding or fixed length decod-
ing for this symbology.
Variable Length:
For variable length decoding, a minimum and maximum
length may be set.
Fixed Length:
For fixed length decoding, two different lengths may be set.
DEFAULT
$CMXLC00(CR)
Maxicode Length Control = Variable Length
$CMXLC01(CR)
Maxicode Length Control = Fixed Length
Maxicode Set Length 1
Specifies one of the bar code lengths for Maxicode Length Control. Length 1 is
the minimum label length if in Variable Length Mode, or the first fixed length
if in Fixed Length Mode. Characters can be set from 000
1 to 0145 charac-
ters in increments of 0001 (pad with zeros).
See page 241 for detailed instructions on setting this feature.
$CMXL1
Select Maxicode Length 1 Setting
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar code
at
left followed by the digits from the Alphanumeric
characters in
Appendix D, Keypad representing your
desired character(s). End by scanning the ENTER/EXIT
bar co
de again.
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start again
at the beginning.
~
CANCEL
DEFAULT
0001 = Length 1 is 1 Character

Table of Contents

Other manuals for Datalogic Gryphon GPS4421

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic Gryphon GPS4421 and is the answer not in the manual?

Datalogic Gryphon GPS4421 Specifications

General IconGeneral
BrandDatalogic
ModelGryphon GPS4421
CategoryScanner
LanguageEnglish

Related product manuals