Software Configuration Strings
206
Gryphon™ GPS4400
SERIAL CONFIGURATION STRINGS
ENTER/EXIT CONFIGURATION COMMANDS
Description Command
S
Exit Service Mode (configuration) return to programmed Baud rate
s
Apply Configuration to RAM (temporary memory) and Exit Service Mode
r01
Apply and Save Configuration to FLASH (permanent memory) and Exit Service
Mode
Ar
CONFIGURATION COMMANDS
Description Command
C
xxxxxx
Read Single Configuration Item from RAM (temporary memory)
c
xxxx
Reset Reader
R
Read Application Software Release (does not require Enter/Exit Service
Mode)
$+$!
Host Commands Obey
CIFIH00
Host Commands Ignore
CIFIH01
Enable All Symbologies
AA
Disable All Symbologies
AD
The Interface Selection commands store and load the new interface type
with its factory defaults into the current configuration.
To configure the reader using configuration strings, it m
ust be placed into
Service Mode, which automatically sets the reader communication to
115200 baud rate. You must therefore set the host accordingly for RS-
232 communications. Upon exiting Service Mode, the programmed baud
rate will be restored.
Enter Service Mode (configuration) fixed 115200 Baud rate
Write Single Configuration Item to RAM (
temporary memory)

Table of Contents

Other manuals for Datalogic Gryphon GPS4421

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic Gryphon GPS4421 and is the answer not in the manual?

Datalogic Gryphon GPS4421 Specifications

General IconGeneral
BrandDatalogic
ModelGryphon GPS4421
CategoryScanner
LanguageEnglish

Related product manuals