SAFETY REPORT GENERATION AND ACCEPTANCE
INSTRUCTION MANUAL
87
SAFETY REPORT GENERATION AND ACCEPTANCE
The Safety Report is a file that sums up all the parameters selected for a configuration
and is generated by the GUI after creating a configuration.
The Report file is displa
yed on the right side of the panel. It is possible to save it as a PDF
file and print it.
Follow the steps below to create the Report file:
1. Once the configuration has been created or loaded, enter the Pr
ogramming func-
tion.
2. Upload the configuration in Configur
ation Upload. The Report file is generated by
the GUI. Make sure to read and check all the selected parameters.
3. Then test its functioning by entering Monit
oring.
4. After testing the configuration in Monit
oring and checking the Report accept or
reject the configuration in Validation.
WARNING
By validating the configuration, you take on responsibility for the created
configuration accepting the hazard due to configuration errors.