DIAGNOSTIC NOTES, WARNINGS, AND ERRORS
INSTRUCTION MANUAL
89
DIAGNOSTIC NOTES, WARNINGS, AND ERRORS
DISPLAYED
ICON
DISPLAYED
FAULT CODE
DEVICE
STATUS
OSSD
STATUS
DESCRIPTION
DLDNF NORMAL OFF Downloading new firmware.
DLDNC
NORMAL OFF Downloading new configuration.
CLEANW2 NORMAL ON
It is suggested to clean the window
to avoid ente
ring lockout condition.
ITLOCKx NORMAL OFF
Interlock. Waiting for the relevant
OS
SD pair to restart.
INFT6 NORMAL ON
Micro integrity test failure. Internal
peripher
al test for non safety rele-
vant functions.
BOOTF NORMAL OFF
Invalid boot. Re-boot the system
unti
l the normal condition is
restored. If warning persists, con-
tact Datalogic Technical Support.
MUT TIMEOUT NORMAL ON
Muting has expired because it is
maintained beyond the maximum
timeo
ut time.
MUTING ERR NORMAL ON
Muting has not activated because
the cor
rect sequence was not fol-
lowed.
MUTING NORMAL ON The Muting function is active.
OVERRIDE ERR NORMAL ON
Override has not been activated
because the cor
rect sequence has
not been followed or there are no
override conditions.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic Laser Sentinel and is the answer not in the manual?

Datalogic Laser Sentinel Specifications

General IconGeneral
BrandDatalogic
ModelLaser Sentinel
CategoryScanner
LanguageEnglish

Related product manuals