EasyManuals Logo

Datalogic Laser Sentinel User Manual

Datalogic Laser Sentinel
152 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #108 background imageLoading...
Page #108 background image
DIAGNOSTICS
90
SAFERY LASER SCANNER
OVERRIDE NORMAL ON The Override function is active
OVERTEMP NORMAL ON
The external temperature is above
the limit.
OVR TIMEOUT NORMAL ON
The Override timeout function has
expi
red.
HIGH REFL-BKG NORMAL ON
A high reflecting background is
detected that could hav
e an impact
on detection capability. Take the
measures described in "Precautions
for Environmental Interference" on
page 11 or reduce/remove the
reflecting background.
CHECK MASTER NORMAL ON
The Slave unit warns against a
pr
oblem on the Master device.
WINDOW REPLACE NORMAL OFF
Window replacement procedure in
pr
ogress.
COMMIT ON FIELD NORMAL OFF
The device needs a commit when it
has been r
estored on field after
window replacement.
SHUT-OFF NORMAL OFF Shut Off function enabled.
RES SHUT-OFF NORMAL OFF Shut Off function disabled.
WAITING CONF LOCKOUT OFF
The device is waiting the first con-
figuration (e.g. after a Factory
Reset)
DISPLAYED
ICON
DISPLAYED
FAULT CODE
DEVICE
STATUS
OSSD
STATUS
DESCRIPTION

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic Laser Sentinel and is the answer not in the manual?

Datalogic Laser Sentinel Specifications

General IconGeneral
BrandDatalogic
ModelLaser Sentinel
CategoryScanner
LanguageEnglish

Related product manuals