MX-E Series Hardware Guide Smartek Cameras
69 Datalogic S.r.l.
Smartek Unterminated Cable Connections
Smartek Camera Notes
Camera performance can be affected by the following conditions:
There is some additional latency between the trigger and image acquisition in this camera compared to others
because it reads the entire frame into the buffer before it starts sending. This does not affect the frame rate, but it can
slow down cycle times if task timing is critical or other network communication is being done. Typically the
GC651M, GC652M, and GC653M models add ten milliseconds compared to the M1xx. The GC2441M model adds
approximately 77 milliseconds compared to the M390.
No Power over Ethernet
No trigger overrun detection.
Strobe trigger pulse length cannot be set; it is the same as shutter time. This should not be a functional problem, but
it is unlike the M-Series and E-Series cameras.
The camera is slow to connect the first time it is connected to the Ethernet port. It may take up to 1 minute because
of the camera’s response time to IP address setting.
The camera does not calculate the frame rate when partial scanning is implemented, so an estimate is listed.
Smartek Camera Unterminated Cable Connections
Sourcing Example

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic MX-E Series and is the answer not in the manual?

Datalogic MX-E Series Specifications

General IconGeneral
BrandDatalogic
ModelMX-E Series
CategoryMachine Vision Systems
LanguageEnglish

Related product manuals