Figure 50. Configuration 21: 8 x2.5 inch (SAS4/SATA) Smart Flow (1 CPU) (fPERC11)
NOTE:
Follow the sequential order as shown in the table to remove the cables, to install the cables follow the reverse
sequential order.
Table 92. 8 x 2.5 inch (SAS4/SATA) Smart Flow (1 CPU) (fPERC11)
Order From To
1 SIG_PWR_1 (system board power
connector)
BP_PWR_1 (backplane power connector)
2 SL3_CPU1_PA2 (signal connector on
system board)
CTRL_DST_PA1 (fPERC input connector)
3 CTRL_SRC_SB1 (fPERC controller
connector)
BP_DST_SA1 (backplane signal connector) and BP_DST_SB1
(backplane signal connector)
4 BP_PWR_CTRL (backplane power
connector)
FPERC_GF
Installing and removing system components 95