Figure 15. Establishing Sessions with BGP Neighbors
The sample conguration shows alternative ways to establish a BFD session with a BGP neighbor:
• By establishing BFD sessions with all neighbors discovered by BGP (the bfd all-neighbors command).
• By establishing a BFD session with a specied BGP neighbor (the neighbor {ip-address | peer-group-name} bfd
command)
BFD packets originating from a router are assigned to the highest priority egress queue to minimize transmission delays. Incoming BFD
control packets received from the BGP neighbor are assigned to the highest priority queue within the control plane policing (COPP)
framework to avoid BFD packets drops due to queue congestion.
BFD noties BGP of any failure conditions that it detects on the link. Recovery actions are initiated by BGP.
BFD for BGP is supported only on directly-connected BGP neighbors and only in BGP IPv4 networks. Up to 128 simultaneous BFD sessions
are supported
As long as each BFD for BGP neighbor receives a BFD control packet within the congured BFD interval for failure detection, the BFD
session remains up and BGP maintains its adjacencies. If a BFD for BGP neighbor does not receive a control packet within the detection
interval, the router informs any clients of the BFD session (other routing protocols) about the failure. It then depends on the individual
routing protocols that uses the BGP link to determine the appropriate response to the failure condition. The typical response is to terminate
the peering session for the routing protocol and reconverge by bypassing the failed neighboring router. A log message is generated
whenever BFD detects a failure condition.
1 Enable BFD globally.
CONFIGURATION mode
bfd enable
2 Specify the AS number and enter ROUTER BGP conguration mode.
Bidirectional Forwarding Detection (BFD)
157

Table of Contents

Other manuals for Dell S3048-ON

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell S3048-ON and is the answer not in the manual?

Dell S3048-ON Specifications

General IconGeneral
Rack Units1U
Form FactorRack-mountable
Input Voltage100-240V AC
Power Supply2 hot-swappable power supplies
ManagementCLI, Web, SNMP
Product TypeSwitch
MAC Address Table Size32K entries
Jumbo Frame SupportYes
Latency< 3 microseconds
Ports48 x 1GbE RJ45, 4 x 10GbE SFP+