Chapter 4 Parameters|
4-132 Revision August 2008, 03VE, SW V2.04
Control
mode
VF VFPG SVC FOCPG TQRPG
Factory Setting: 1
Settings 1 to 10000ppr
08-50 Coil Number for Each Layer Unit: 1
Control
mode
VF VFPG SVC FOCPG TQRPG
Factory Setting: 1
Settings 1 to 10000
08-51 Material Thickness Unit: 0.001
Control
mode
VF VFPG SVC FOCPG TQRPG
Factory Setting: 1.000
Settings 0.001 to 60.000mm
08-52 Filter Time of Reel Diameter Unit: 0.01
Control
mode
VF VFPG SVC FOCPG TQRPG
Factory Setting: 1.00
Settings 0.00 to 100.00 sec
This parameter can be used to improve unstable of the source of reel diameter(Pr.08-42).
08-53 Auto Compensation of Reel Diameter
Control
mode
VF VFPG SVC FOCPG TQRPG
Factory Setting: 0
Settings 0 Disable
1 Enable
08-54 Current Reel Diameter Unit: 0.1
Control
mode
VF VFPG SVC FOCPG TQRPG
Factory Setting: 1.0
Settings 1.0 to 6000.0 mm
When the AC motor drive is not at STOP, this parameter is read-only.
08-55 Smart Start
Control
mode
VF VFPG SVC FOCPG TQRPG
Factory Setting: 0
Settings 0 Disable
1 Enable
2 In unwind mode, rewind in reverse direction
08-56 Switch Level for Smart Start and PID Function Unit: 1
Control
mode
VF VFPG SVC FOCPG TQRPG
Factory Setting: 15.0