EasyManua.ls Logo

Delta Electronics AC Motor Drive VFD-VE Series - Auto-Tuning Tension PID; Tension PID P1

Delta Electronics AC Motor Drive VFD-VE Series
291 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 4 Parameters|
Revision August 2008, 03VE, SW V2.04 4-127
Control
mode
VF VFPG SVC FOCPG TQRPG
Factory Setting: 0
Settings 0 Analog input (Pr. 03-00~03-02 is set to 11 PID feedback of tension)
1 Pulse input (Pr.08-40)
08-28 Auto-tuning Tension PID
Control
mode
VF VFPG SVC FOCPG TQRPG
Factory Setting: 0
Settings 0 Disable
1 Reel diameter (08-29~08-31corresponds to 08-44, 08-32~08-34
corresponds to 08-43)
2 Frequency (08-29~08-31 corresponds to 01-07, 08-32~08-34
corresponds to 01-00)
When Pr.08-28 is set to 1:
08-29
08-30
P.I . D
0
08-32
08-33
08-44 08-43
Dmax
Dmin
reel
diameter
When Pr.08-28 is set to 2:
Fmax
Fmin
08-29
08-30
P.I.D
0
08-32
08-33
01-0
7
01-00
output
frequency
08-29 Tension PID P1 Unit: 0.1

Table of Contents

Related product manuals