Chapter 4 Parameters|
4-128 Revision August 2008, 03VE, SW V2.04
Control
mode
VF VFPG SVC FOCPG TQRPG
Factory Setting: 50.0
Settings 0.0 to 1000.0
08-30 Tension PID I1 Unit: 0.01
Control
mode
VF VFPG SVC FOCPG TQRPG
Factory Setting: 1.00
Settings 0.00 to 500.00 sec
08-31 Reserved
08-32 Tension PID P2 Unit: 0.1
Control
mode
VF VFPG SVC FOCPG TQRPG
Factory Setting: 50.0
Settings 0.0 to 1000.0
08-33 Tension PID I2 Unit: 0.01
Control
mode
VF VFPG SVC FOCPG TQRPG
Factory Setting: 1.00
Settings 0.00 to 500.00 sec
08-34 Reserved
08-35 PID Output Status
Control
mode
VF VFPG SVC FOCPG TQRPG
Factory Setting: 0
Settings 0 Positive output
1 Negative output
08-36 Tension/Line Speed PID Output Limit Unit: 0.01
Control
mode
VF VFPG SVC FOCPG TQRPG
Factory Setting: 20.00
Settings 0 to 100.00% (according to Pr.01-00)
08-37 Source of Line Speed Input Command
Control
mode
VF VFPG SVC FOCPG TQRPG
Factory Setting: 0
Settings 0 Disable
1 Analog input (Pr. 03-00~03-02 is set to 12 line speed)
2 RS-485 communication setting (Pr.08-41)