Chapter 4 Parameters|
Revision August 2008, 03VE, SW V2.04 4-135
Settings 0.00~100.00 sec
08-71
|
08-75
Reserved
08-76 Source of Tension Setting
Control
mode
TQRPG
Factory Setting: 0
Settings 0 Communication RS-485 (Pr.08-78)
1 Analog input (Pr. 03-00~03-02 is set to 15 tension setting) (Pr.08-78)
08-77 Max. Tension Unit: 1
Control
mode
TQRPG
Factory Setting: 0
Settings 0 ~30000 N
08-78 Tension Setting Unit: 1
Control
mode
TQRPG
Factory Setting: 0
Settings 0 ~30000 N
08-79 Source of Zero-speed Tension Setting
Control
mode
TQRPG
Factory Setting: 0
Settings 0 Disable
1 Communication RS-485 (Pr.08-80)
2 Analog input (Pr. 03-00~03-02 is set to 16 zero-speed tension)
(Pr.08-80)
08-80 Setting of Zero-speed Tension Unit: 1
Control
mode
TQRPG
Factory Setting: 0
Settings 0 ~30000 N
08-81 Source of Tension Taper
Control
mode
TQRPG
Factory Setting: 0
Settings 0 Communication RS-485 (Pr.08-82)
1 Analog input (Pr. 03-00~03-02 is set to 17 tension taper) (Pr.08-82)
08-82 Tension Taper Unit: 1