Chapter 4 Parameters|
4-164 Revision August 2008, 03VE, SW V2.04
Settings 0.001 to 65.535 Sec
 It is used to lower the blinking frequency of LCD display.
11-17  Low-pass Filter Time of PG2 Pulse Input Unit: 0.001
Control
mode
VF VFPG SVC FOCPG
Factory Setting: 0.100
Settings 0.000 to 65.535 Sec
11-18  APR Gain Unit: 0.01
Control
mode
FOCPG
Factory Setting: 10.00
Settings 0.00 to 40.00
11-19  APR Curve Time Unit: 0.01
Control
mode
FOCPG
Factory Setting: 3.00
Settings 0.00 to 655.35 sec
11-20
|
11-28
Reserved
11-29 Accumulative Operation Time of Phase-loss Unit: 1
Control
mode
VF VFPG SVC FOCPG TQRPG
Factory Setting: 0
Settings 0 to 65535 (hour)
11-30
|
11-40
Reserved