EasyManua.ls Logo

Delta Electronics AC Motor Drive VFD-VE Series - MO3~MOA Multi-Function Output Terminals (Photocoupler); Multi-Function Output Common Terminal; Analog Signal Common Terminal; Multi-Function Input Terminals

Delta Electronics AC Motor Drive VFD-VE Series
291 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendix B Accessories|
Revision August 2008, 03VE, SW V2.04 B-41
Terminals Description
5V Output power 500mA Max
GND Analog signal common terminal
NOTE
This GND terminal is only used for 5V terminal on EMV-APP01. Please do NOT
confuse with DCM terminal.
SO1-MCM
SO2-MCM
Multi-function analog voltage output terminal 0~10.0V (output current: 2mA Max.)
Analog output is set by Pr.03-21 and Pr.03-24.
MI7~MIB Multi-function input terminals
Please refer to Pr.02-23 to Pr.02-27 for MI7-GND~MIB-GND function selection. Take
terminals MI7-GND for example, ON: the activation current is 6.5mA and OFF:
leakage current tolerance is 10μA.
MO3~MOA Multi-function output terminals (photocoupler)
The AC motor drive outputs each monitor signal, such as during operation, frequency
attained and overload, by transistor with open collector. Please refer to Pr.03-35 to
Pr.03-42 for details.
MO3~MOA-MCM
MO3
~
MOA
MCM
Max: 48Vdc/50mA
internal c ircuit
MCM Multi-function output common terminal. Max: 48Vdc/50mA
NOTE
This MCM terminal is only used with MO3~MOA on EMV-APP01. Please do NOT
confuse with terminal MCM.

Table of Contents