EasyManuals Logo

Delta Electronics AC Motor Drive VFD-VE Series User Manual

Delta Electronics AC Motor Drive VFD-VE Series
291 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #66 background imageLoading...
Page #66 background image
Chapter 4 Parameters|
Revision August 2008, 03VE, SW V2.04 4-17
Pr. Explanation Settings
Factory
Setting
VF VFPG
SVC
FOCPG
TQRPG
07-27
Source of Torque
Offset
0: Disable
1: Analog input (Pr.03-00)
2: Torque offset setting
3: Control by external terminal (by Pr.07-29 to Pr.07-
31)
0
â—‹ â—‹ â—‹
07-28
Torque Offset Setting 0.0~100.0% 0.0
â—‹ â—‹ â—‹
07-29
High Torque Offset 0.0~100.0% 30.0
â—‹ â—‹ â—‹
07-30
Middle Torque Offset 0.0~100.0% 20.0
â—‹ â—‹ â—‹
07-31
Low Torque Offset 0.0~100.0% 10.0
â—‹ â—‹ â—‹
07-32
Forward Motor Torque
Limit
0~500% 200
â—‹ â—‹
07-33
Forward Regenerative
Torque Limit
0~500% 200
â—‹ â—‹
07-34
Reverse Motor Torque
Limit
0~500% 200
â—‹ â—‹
07-35
Reverse Regenerative
Torque Limit
0~500% 200
â—‹ â—‹
07-36
Emergency Stop (EF)
& Forced Stop
Selection
0: Coast stop
1: By deceleration Time 1
2: By deceleration Time 2
3: By deceleration Time 3
4: By deceleration Time 4
5: System Deceleration
6: Automatic Deceleration
0
â—‹ â—‹ â—‹ â—‹ â—‹

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta Electronics AC Motor Drive VFD-VE Series and is the answer not in the manual?

Delta Electronics AC Motor Drive VFD-VE Series Specifications

General IconGeneral
BrandDelta Electronics
ModelAC Motor Drive VFD-VE Series
CategoryController
LanguageEnglish

Related product manuals