Interfaces Wide Area Networks (WANs)
Digi Connect IT® 16/48 User Guide
66
6. Add a test target:
(config network interface my_wan)> add ipv4 surelink target end
(config network interface my_wan ipv4 surelink target 0)>
7. Set the test type:
(config network interface my_wan ipv4 surelink target 0)> test value
(config network interface my_wan ipv4 surelink target 0)>
where value is one of:
n ping: Tests connectivity by sending an ICMP echo request to a specified hostname or IP
address.
l Specify the hostname or IP address:
(config network interface my_wan ipv4 surelink target 0)> ping_
host host
(config network interface my_wan ipv4 surelink target 0)>
l (Optional) Set the size, in bytes, of the ping packet:
(config network interface my_wan ipv4 surelink target 0)> ping_
size [num]
(config network interface my_wan ipv4 surelink target 0)>
n dns: Tests connectivity by sending a DNS query to the specified DNS server.
l Specify the DNS server. Allowed value is the IP address of the DNS server.
(config network interface my_wan ipv4 surelink target 0)> dns_
server ip_address
(config network interface my_wan ipv4 surelink target 0)>
n dns_configured: Tests connectivity by sending a DNS query to the DNS servers
configured for this interface.
n http: Tests connectivity by sending an HTTP or HTTPS GET request to the specified URL.
l Specify the url:
(config network interface my_wan ipv4 surelink target 0)> http_url
value
(config network interface my_wan ipv4 surelink target 0)>
where value uses the format http[s]://hostname/[path]
n interface_up: The interface is considered to be down based on the interfaces down
time, and the amount of time an initial connection to the interface takes before this
test is considered to have failed.
l (Optional) Set the amount of time that the interface can be down before this test is
considered to have failed: