Serial port Configure Remote Access mode
IX30 User Guide
220
13. Configure monitor settings.
a. (Optional) Enable monitoring of CTS (Clear to Send) changes on this port:
(config)>serial port1 monitor cts true
(config)
b. (Optional) Enable monitoring of DCD (Data Carrier Detect) changes on this port:
(config)>serial port1 monitor dcd true
(config)
14. (Optional) Configure autoconnect:
a. Enable autoconnect:
(config)>serial port1 autoconnect enable true
(config)>
b. Set the option that will trigger the connection:
(config)>serial port1 autoconnect trigger value
(config)>
where value is one of:
n
always
n
data
n
dcd
n
destination
n
dsr
n
match
If match is selected:
i. Set the string that, when received, will trigger the connection:
(config)>serial port1 autoconnect match_string string
(config)>
ii. flush_string is enabled by default, which will discard the matched string from
data sent to the server. To disable:
(config)>serial port1 autoconnect flush_string false
(config)>
The default is always.
c. Set the option that initiates the connection:
(config)>serial port1 autoconnect conn_type value
(config)>
where value is one of:
n
ssh
n
tcp

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Digi IX30 and is the answer not in the manual?

Digi IX30 Specifications

General IconGeneral
CategoryNetwork Router
ModelIX30
Serial Ports1 x RS-232
Operating Temperature-40° C to 70° C
ConnectivityEthernet
USB Ports1 x USB 2.0
Cellular Interface4G LTE Cat 4
Wi-Fi802.11 a/b/g/n/ac
SIM Slots1
ProcessorARM Cortex-A9
Memory1 GB RAM

Related product manuals